Model | Description | Software Model Number |
DFUW, DUWC, VUWC | 24 inch Wine Cellar | 11 |
DFUR, DUAR, VUAR | 24 inch Beverage Center | 21 |
DFRD, DURD, VURD | 24 inch Refrigerated Drawers | 16 |
Viking Refrigerator Diagnostic Details
Solution Diagnostics Mode allows you to determine the firmware and also software application variations, test condition of “model specific” system components and sensors, and also alter state of elements where suitable (i.e.– compressor on/off, and so on.).
Enabling Service Setting: To make it possible for Service Mode, press and hold the “WARMER” switch while pushing the “COLDER” button 4 times within five seconds.
After getting in Solution Setting, the very first number that you will certainly see indicates the software program design number for the particular unit you are servicing. For instance, if you are servicing a 24 inch wine rack (DFUW, DUWC, VUWC), the first number you will certainly see is 11. See chart listed below for matching model and software application referral.
The 2nd number you will certainly see suggests the software program variation release. As an example, if you see 44 on the display panel it suggests software program version 4.4.
Diagnostics:
While in Service Mode, press the “COLLECTION” switch to tip with Tests 0-9. The initial figure of the display will reveal the test number. The second digit shows the existing state of each component under test and is displayed as “1” getting on, CLOSED, or SHORTED and also “0” being OFF or OPEN. Tests 0 and also 1 expose an open or shorted problem found at the sensing unit inputs. Tests 2 with 6 permit you to transform loads ON with the “WARMER” switch and also OFF with the “COLDER” switch. Examinations 7 with 9 confirm state change of the door switches over and/or magnetic reed sensor. The element tests available are explained in Readily available Component Examinations chart.
PROBLEM | POSSIBLE CAUSE | WHAT TO DO |
Refrigerator or ice maker makes unfamiliar sounds or seems too loud | Normal operation |